On 10/27/2007 11:08 AM, Grant wrote: > I've switched to RPC mode to prevent intermittent 500 errors in my > catalog, but now when I browse my catalog there comes a time when the > server will not respond. Restarting IC always fixes it. I'm on 5.2. > Is an upgrade the preferred solution, or is that unlikely to make a > difference? I'm using the following settings: > > PreFork Yes > StartServers 5 > MaxServers 0 > MaxRequestsPerChild 100 > HouseKeeping 2 > PIDcheck 120 Try lowering MaxRequestsPerChild to 50 or lower. Peter _______________________________________________ interchange-users mailing list suppressed http://www.icdevgroup.org/mailman/listinfo/interchange-users
Mail converted by mhonarc 2.6.15
This archive provided courtesy of JSW4.NET, Internet Hosting Services for Small Business.